Sala Polivalentă, Bucharest · 1974
The roof on cables
Sala Polivalentă’s roof spans 67.5 metres over the arena. What is under the roof skin? And why would a flatter cable pull harder on its anchors?
Horizontal pull in the model
Sixteen trusses across the arena
The roof built in 1974 has sixteen cable trusses. They run in parallel, 4.5 metres apart. The upper cables span 67.5 metres between their anchors.
Tineretului Park · 1974
What holds the roof over the arena?
From inside the arena you see a continuous surface. Look toward its edges. Under the skin sit sixteen cable trusses at intervals of 4.5 metres. To understand the whole roof, follow one of them from end to end.
Two above, one below
Look down the end of one truss. Two groups of load-bearing cables sit above, 1.80 metres apart. One group of tensioning cables closes the triangle below. Diagonals connect the groups along the span.
- Load-bearing cables
- Tensioning cables
- Diagonal connections
One truss from the end
Two cable groups above, one below
In the engineer’s drawing the two upper groups are 1.80 metres apart. The tensioning group runs underneath. Diagonals connect the three. From the end, the truss has a triangular section.
The upper groups span 67.5 metres. The lower group spans 63.3 metres.
The engineer’s drawing
Each cable has two ends
Follow the cables to the edge. The drawing gives the position and height of each anchor. The model joins those points with approximate curves so you can follow a truss across the opening. The span, truss spacing and anchor positions come from the drawings.
How hard a cable pulls at its ends
The demonstration uses a single cable, supported at both ends. With the same weight distributed across the span, the flatter cable pulls harder horizontally on the anchors.
This demonstration uses an idealized parabolic cable. It gives no estimate of how far the building moves or whether it is safe.
Change the cable’s sag
A flatter cable pulls harder
The demonstration isolates one cable supported at both ends. Keep the distributed load per horizontal metre the same and reduce the midpoint sag: the horizontal pull on each end rises. The model uses H = q·L²/(8f), with span L and sag f.
Keep the load and change the sag
Same load, from 91 to 228 kN
At q = 0.8 kN/m and L = 67.5 m, an idealized cable with 5 metres of sag needs about 91.1 kN of horizontal pull at each end. Reduce the sag to 2 metres: the calculation gives 227.8 kN. This shows geometry’s effect in an example; it does not describe the real roof’s response or safety.
Why a cable’s shape matters
In the single-cable example, the span and load stayed fixed. The midpoint sag changed, and the pull at the ends rose. Go back to the whole roof and you can see where each cable carries its load. Sala Polivalentă’s trusses have linked cable groups. The example isolates the effect of sag, and the drawings show how the roof is put together.
The roof in the drawings
The model follows dimensions and arrangement published by engineer Elena Crăilă in her dissertation, chapter 5.2, plates 1/1 and 1/2. The cable curves and the rest of the building are simplified.