Physiological model · Coburn–Forster–Kane · EN 50291
Your kitchen gas detector cannot sense carbon monoxide
Carbon monoxide has no smell or colour and binds hemoglobin 218 times more tightly than oxygen. Eastern Europe holds the highest unintentional CO mortality rate worldwide — nearly six times the global average — while kitchen methane alarms stay completely silent.
Why a fingertip pulse oximeter still reads 99% during poisoning
Standard pulse oximeters compare light absorption at 660 nm (red) and 940 nm (infrared). Carboxyhemoglobin absorbs 660 nm light almost like oxygenated hemoglobin, causing fingertip devices to display a falsely reassuring percentage even during severe hypoxia.
Why opening a window does not clear your blood right away
Once locked onto hemoglobin, carbon monoxide clears slowly: its half-life exceeds four and a half hours in fresh air, drops to about 74 minutes on 100% oxygen via non-rebreather mask, and reaches roughly 23 minutes in hyperbaric oxygen.
Methane detector ≠ CO detector: what each alarm catches
Combustible-gas alarms (EN 50194) are built to prevent natural-gas explosions. They are chemically blind to carbon monoxide from blocked chimneys or faulty boilers. Protect sleeping areas with a separate EN 50291 CO alarm.
| Alarm type | Standard | What it senses | Mounting height |
|---|---|---|---|
| Methane detector | EN 50194 | Natural gas (CH₄) leaks — explosion prevention | High, 15–30 cm below ceiling |
| Carbon monoxide alarm | EN 50291 | Carbon monoxide (CO) from incomplete combustion | Breathing height / bedroom wall |
| Smoke alarm | EN 14604 | Visible smoke particles from fire | Ceiling in hallways & bedrooms |
| LPG detector | EN 50194 | Propane and butane cylinder leaks | Low, 15–30 cm above floor |
EN 50291-1:2018 alarm windows and WHO air limits
| Concentration | EN 50291-1:2018 alarm window |
|---|---|
| 30 ppm | Must NOT alarm before 120 minutes |
| 50 ppm | Must alarm between 60 and 90 minutes |
| 100 ppm | Must alarm between 10 and 40 minutes |
| 300 ppm | Must alarm in under 3 minutes |
| Averaging period | WHO guideline | Approx. ppm | Edition |
|---|---|---|---|
| 15 minutes | 100 mg/m³ | ~87 ppm | 2010 / 2021 |
| 1 hour | 35 mg/m³ | ~30 ppm | 2010 / 2021 |
| 8 hours | 10 mg/m³ | ~9 ppm | 2010 / 2021 |
| 24 hours | 4 mg/m³ | ~3.5 ppm | 2021 (nou) |
Get into fresh air immediately
Open doors and windows on your way out and evacuate every person and pet.
Call 112 / 999 / 911 from outside
State suspected carbon monoxide exposure explicitly, especially if multiple people feel dizzy or nauseated.
Shut fuel off only if safe
Close the gas valve or boiler power only if doing so adds no indoor exposure.
Never re-enter the room
Wait for fire crews or a licensed technician to clear and repair the appliance.
Ask paramedics for co-oximetry
Remind clinicians of CO exposure so they measure SpCO instead of relying on fingertip SpO₂.
Global data, equations and model limits
The Global Burden of Disease 2021 study (The Lancet Public Health, Nov 2023) estimates 28,900 unintentional CO poisoning deaths annually, with Eastern Europe highest globally at 2.12 per 100,000 (vs 0.366 global mean). Blood uptake uses the Coburn–Forster–Kane differential equation (M = 218, endogenous V_CO = 0.007 mL/min) calibrated to WHO's 2% COHb limit. Scenario emission rates are illustrative fault magnitudes, not appliance diagnostics.
- GBD 2021 Carbon Monoxide Poisoning Collaborators — The Lancet Public Health (2023)
- WHO Guidelines for Indoor Air Quality: Selected Pollutants (2010, NBK138710)
- Coburn R.F., Forster R.E., Kane P.B. (1965), J. Clin. Invest. 44(11); Peterson J.E., Stewart R.D. (1975), J. Appl. Physiol. 39(4)
- EN 50291-1:2018 (CO alarms) · EN 50194 (Combustible gas alarms) · Barker & Tremper (1987), Anesthesiology 66(5) · Weaver et al. (2002), NEJM 347