Chapter 3 · Redox and cellsLesson 3.8TC Core curriculum (1 hour a week) · beyond your profile
Applications: electrochemical cells (the Daniell cell, lead–acid battery, lithium-ion battery) – construction and operation; conventional representation of the Daniell cell
What happens inside the battery that starts a car
A car battery contains lead and sulfuric acid. Why does it go flat, and how can it be charged again?
Before you read: what do you think?
A car battery is discharging. What happens to the liquid inside it, a solution of sulfuric acid in water?
See the answer
Discharge uses up sulfuric acid and produces water, so the solution becomes more dilute and its density falls. The density tells you how charged the battery is.
On a winter morning, the starter motor turns more and more slowly, then just clicks: the battery has gone flat. A mechanic draws a little liquid from its cells into an instrument with a float, a hydrometer, and reads its density. The reading shows how much sulfuric acid remains in the solution, and so how charged the battery is.
Six cells in one caseWhat you see
A car battery has six compartments, called cells, connected in series. Each cell contains lead plates, Pb, and plates coated with lead dioxide, PbO₂, separated by a porous layer that stops them touching. All are immersed in a solution of sulfuric acid, H₂SO₄, which contains approximately 36% acid by mass when the battery is charged.
The Pb plates are the negative electrode, and the PbO₂ plates are the positive electrode. A charged cell has approximately 2.1 V, and the six cells in series give approximately 12.6 V, the reading a voltmeter shows across the terminals of a charged battery. The calculation “6 · 2 V = 12 V” is a rounding.
A battery can supply very large currents for a few seconds, as the starter motor requires, while the acid solution between the plates conducts current through ions. That is why the lead–acid battery is still used to start internal combustion engines.
For the curious
The lead–acid battery was invented in 1859 by the French physicist Gaston Planté and was the first rechargeable battery used commercially. It is still one of the cheapest batteries for the power it delivers.
On discharge, both plates become lead sulfateWhat the particles do
At the lead plates, each Pb atom gives up two electrons and combines with sulfate ions from the solution. Lead sulfate, PbSO₄, forms as a solid that coats the plate. The oxidation number of lead rises from 0 to +2.
At the PbO₂ plates, lead has an oxidation number of +4. It gains two electrons, reaches +2 and also bonds to sulfate ions, forming PbSO₄. Hydrogen ions from the acid and oxygen from PbO₂ form water.
Electrons leave the Pb plates, pass through the external circuit, for example through the starter motor, and reach the PbO₂ plates. In the solution, ions carry the charge. Sulfate ions enter PbSO₄, and H⁺ ions form water, so the solution becomes more dilute and its density falls.
The discharge and charging equationsHow it is written
On discharge, the Pb plates are the anode (oxidation), and the PbO₂ plates are the cathode (reduction):
Negative electrode (anode), oxidation: Pb + SO₄²⁻ → PbSO₄ + 2e⁻
Positive electrode (cathode), reduction: PbO₂ + 4H⁺ + SO₄²⁻ + 2e⁻ → PbSO₄ + 2H₂O
The number of electrons given up equals the number gained. Adding the equations and grouping the ions into acid gives the overall discharge equation:
Pb + PbO₂ + 2H₂SO₄ → 2PbSO₄ + 2H₂O
Charging is the reverse reaction, driven by an electric current sent into the battery by the car’s alternator or a charger:
2PbSO₄ + 2H₂O → Pb + PbO₂ + 2H₂SO₄
The reverse reaction does not happen on its own. During charging, oxidation and reduction switch plates: PbSO₄ on the negative plate is reduced to Pb, and PbSO₄ on the positive plate is oxidised to PbO₂. That is why the battery’s plates are called the “negative electrode” and “positive electrode”: their signs stay the same, while their roles as anode and cathode change.
How density shows the state of chargeWhat you see
A charged battery and a discharged one contain the same elements in different substances: Pb, PbO₂ and H₂SO₄ in the first, PbSO₄ and more water in the second. As acid is used up, the solution’s density and the battery’s voltage fall. For a car battery whose solution has a density of 1.265 g/cm³ at full charge, a standard table gives: 100% charge, 1.265 g/cm³ and 12.65 V; 50% charge, 1.190 g/cm³ and 12.24 V; 0% charge, 1.120 g/cm³ and 11.89 V.
Lead is toxic, and sulfuric acid is corrosive. Do not open the battery at home or put it in the bin: take it for recycling.
Worked example
The balance in a discharging cell
A cell uses up 20.7 g of lead. What masses of PbO₂ and H₂SO₄ are used up, and what masses of PbSO₄ and H₂O form? M(Pb) = 207 g/mol, M(PbO₂) = 239 g/mol, M(H₂SO₄) = 98 g/mol, M(PbSO₄) = 303 g/mol, M(H₂O) = 18 g/mol.
n(Pb) = 20.7 ÷ 207 = 0.10 mol. From Pb + PbO₂ + 2H₂SO₄ → 2PbSO₄ + 2H₂O, n(PbO₂) = 0.10 mol, n(H₂SO₄) = 0.20 mol, n(PbSO₄) = 0.20 mol and n(H₂O) = 0.20 mol.
m(PbO₂) = 0.10 · 239 = 23.9 g; m(H₂SO₄) = 0.20 · 98 = 19.6 g; m(PbSO₄) = 0.20 · 303 = 60.6 g; m(H₂O) = 0.20 · 18 = 3.6 g.
Check: the reactants have a mass of 20.7 + 23.9 + 19.6 = 64.2 g, and the products 60.6 + 3.6 = 64.2 g.
Effect on the solution: if it had 1,000 g with 36% acid, or 360 g of H₂SO₄, then 360 − 19.6 = 340.4 g of acid remain in 1,000 − 19.6 + 3.6 = 984 g of solution, so c = 340.4 · 100 ÷ 984 ≈ 34.6%. The concentration has fallen.
In Romania
Batteries made in Bistrița and recycled in Copșa Mică
Batteries have been made in Bistrița for over 45 years. In 1980, Acumulatorul Bistrița was a division of a state-owned company; by 1996, under the name Rombat, the factory was fully privatised and supplied batteries for Dacia in Pitești. Today Rombat exports batteries to 45 countries.
In 2005, Rombat opened the Rebat centre in Copșa Mică to recycle used batteries. According to the company, it recycles an average of over 24,000 tonnes of batteries there each year and recovers up to 99% of the contents of collected batteries. Recycling is necessary precisely because lead is toxic.
In short
- A lead–acid battery has Pb plates (the negative electrode) and PbO₂ plates (the positive electrode) in a solution of approximately 36% sulfuric acid; one cell gives approximately 2.1 V, and six cells give approximately 12.6 V.
- On discharge, lead is oxidised from 0 to +2 at the negative electrode and reduced from +4 to +2 at the positive electrode; both plates become PbSO₄.
- The discharge equation is Pb + PbO₂ + 2H₂SO₄ → 2PbSO₄ + 2H₂O; charging is the reverse reaction, driven by an electric current.
- On discharge, acid is used up and water forms, so the solution’s density falls; the density shows the state of charge.
- During charging the plates switch roles as anode and cathode, but their signs stay the same: that is why they are called the negative electrode and positive electrode.
- Lead is toxic: the battery is recycled.
Common mistakes
WrongOnly the lead plates are used up during discharge.
RightBoth plates, Pb and PbO₂, turn into PbSO₄, and sulfuric acid is also used up.
WrongCharging is the reverse reaction and happens on its own.
RightThe reverse reaction does not happen on its own. It needs an electric current from the alternator or a charger.
WrongA charged car battery has exactly 12 V because each cell has exactly 2 V.
RightA charged cell has approximately 2.1 V, so the battery has approximately 12.6 V. The value 12 V is a rounding.
Test yourself
7 questions. For the first 6 you see the explanation at once, with the paragraph of the lesson that supports it; for the written ones you compare with a good answer.
In a lead–acid battery, with Pb and PbO₂ plates in H₂SO₄ solution, what substance forms at both types of plate during discharge?
Answer
c) Lead sulfate, PbSO₄. Metallic lead is oxidised to +2, and the lead in PbO₂ is reduced to +2; in both cases it bonds to sulfate ions and forms PbSO₄.
How does the H₂SO₄ solution in a lead–acid battery change during discharge?
Answer
a) H₂SO₄ is used up and water forms, so the density falls. The discharge equation shows that acid is used up and water forms: the solution becomes more dilute.
Why are the plates in a lead–acid battery called the “negative electrode” and “positive electrode” rather than the anode and cathode?
Answer
d) Because the plates switch roles as anode and cathode during charging, while their signs stay the same. On discharge the Pb plates are the anode; during charging they are the cathode. The sign of the plate does not change.
During discharge of a lead–acid battery, the reaction Pb + PbO₂ + 2H₂SO₄ → 2PbSO₄ + 2H₂O takes place in a cell. It uses up 0.050 mol of lead. What mass of H₂SO₄ is used up? M(H₂SO₄) = 98 g/mol. Answer in grams, to one decimal place.
gAnswer
9.8 g. For every 1 mol of Pb, 2 mol of H₂SO₄ are used up: n = 2 · 0.050 = 0.10 mol, and m = 0.10 · 98 = 9.8 g.
A charged cell of a lead–acid battery has 2.1 V, and the battery has six cells connected in series. What is the battery voltage, in volts?
VAnswer
12.6 V. The voltages of cells connected in series add up: 6 · 2.1 = 12.6 V.
In a lead–acid battery (Pb and PbO₂ in H₂SO₄), does each statement describe discharge or charging? Place each statement under the right process.
Answer
During discharge: Sulfuric acid is used up; PbSO₄ forms on both plates; The solution’s density falls.
During charging: Pb and PbO₂ form; An electric current is sent into the battery; Sulfuric acid forms.
Discharge turns Pb and PbO₂ into PbSO₄ and uses up acid; charging is the reverse reaction, driven by an electric current.
A mechanic measures the density of the H₂SO₄ solution in a cell of a lead–acid battery and finds 1.12 g/cm³, rather than 1.265 g/cm³ (the value when charged). What does this say about the battery, and what has happened inside it?
A good answer
The battery is almost discharged. During discharge, sulfuric acid was used up and water formed, so the solution became more dilute and its density fell. The Pb and PbO₂ plates turned into PbSO₄. To use it again, the battery must be charged with an electric current, which reverses the reaction.
A complete answer links the low density to the use of acid and formation of water, names the product PbSO₄ and says that charging requires an electric current.
Terms
- rechargeable battery
- An electrochemical cell whose redox reaction can be reversed by charging with an electric current, so it can be used more than once.
- cell
- The unit of a battery, made of two electrodes and the solution between them; a car battery has six, connected in series.
- negative electrode
- The Pb electrode; on discharge it is the anode, where oxidation takes place.
- positive electrode
- The PbO₂ electrode; on discharge it is the cathode, where reduction takes place.
- lead sulfate
- PbSO₄, the solid that forms on both plates during discharge.
- discharge
- The operation of the battery as a source of current: Pb + PbO₂ + 2H₂SO₄ → 2PbSO₄ + 2H₂O.
- charging
- The reverse of the discharge reaction, driven by an electric current sent into the battery.
Sources and link to the programme
- OpenStax – Chemistry 2e, 17.5 Batteries and Fuel Cells – lead–acid battery reactions, overall equation, cell of approximately 2 V, six cells connected in series for 12 V, proper disposal of lead–acid batteries
- Battery University – BU-903: How to Measure State-of-charge – table of density and voltage by state of charge: 1.265 and 2.10 V per cell (12.65 V) at full charge, 1.120 and 11.89 V at discharge; falling density as acid becomes bound in lead sulfate
- Battery University – BU-201: How does the Lead Acid Battery Work? – lead–acid battery invented by Gaston Planté in 1859, the first commercial rechargeable battery; use as a starter battery; lead and sulfuric acid as environmental problems
- US Army TM 5-3820-256-24-4 – Battery electrolyte and specific gravity – density of 1.265 at full charge, corresponding to approximately 36% sulfuric acid by mass
- Comisia Europeană – Batteries (Regulation (EU) 2023/1542) – improper battery disposal releases toxic lead, cadmium and mercury into soil and water
- Rombat – Despre noi – history of the Bistrița factory: division of a state-owned company in 1980, fully privatised joint-stock company in 1996, supplier to Dacia Pitești; exports to 45 countries
- Rombat – Sustenabilitate – Rebat centre in Copșa Mică, opened in 2005: an average of over 24,000 tonnes of used batteries recycled per year, recovery of up to 99% of the contents
From the programme: “Applications: electrochemical cells (the Daniell cell, lead–acid battery, lithium-ion battery) – construction and operation; conventional representation of the Daniell cell”; “Applications: electrochemical cells (the Daniell cell, lead–acid battery, lithium-ion battery) – construction and overall reaction equation; conventional representation of the Daniell cell” (TC: Core curriculum (1 hour a week)). Specific competences followed: 1.2, 2.2, 4.2, 5.2, 6.2.